(least possibility according to my experience). (Aspire coil fit issue with a non-Aspire tank).Ħ. Poor or improper fit of the coil head into the atty base. Poor connection between the 510 and tank 510 connection.ĥ. My profile setting is pre-heat = 100, punch =5, temp setting 400F, wattage setting= 24.1 and e-liquid is 70/30 VG/PG.ģ. My vaping resistance goes from 0.15 to 0.27 while vaping and reaching temp limit. The resistance swing of the coil while I vape it varies 0.12 ohms. You can then use the atty analyzer while putting pressure on the center pin while looking at the Device monitor but you will need to put pressure before connecting the device to Escribe and running the analyzer. You will need to put downward pressure on the center pin of the atty base with the ohm meter lead so you get a good connection at the center pin since the coil is not screwed into the base. Measure the ohm's with your ohm meter while not firing the device. Would be curious what ohm reading you will get by taking off the tank and coil and screwing the base only into the device. Cold ohm's at 0.20 or 0.22 going to 0.34 when the coil is cold also at 0.34. What is strangest of all is that you let the device rest for an hour and the ohm's goes to 0.34. I've ran probably at least 40 temp and non-temp Aspire coils in a set of Atlantis tanks. So the Efusion has the proper settings from the manufacturer (or you ran the analyzers and set it up yourself)? Many things can cause what you are getting. Really appreciate any input to this issue.Įdit: To add to the confusion the coil keeps dropping out of temp control between vapes and will only go back into temp control if I lock the Ohm's. Should I lock the Ohms for an ni200 coil when its first used? Kind of confused on this as I've read to not lock a dna200 for it to be accurate. Vape on it, take the tank off and put it back on and get prompted new coil and ohms drop to 0.27, Anyone know whats going on? To add to my confusion now after vaping and letting the tank sit for an hour or so now the ohms read 0.34. ex:0.22Ohm coil will drop to 0.20ohm after I upload settings and fire the first time asking new coil. Just working the first one in and it will actually drop ohms and ask new coil every time I adjust settings in Escribe. I picked up some Aspire trition 0.15Ohm ni200 coils for my driving tank, Project sub-ohm saucecode.įirst I'll say the pack I got are labeled 0.15Ohm, but I've checked 2 of the 5 and both read 0.22Ohms on an ohm meter and on my Efusion.